Refrigerated Truck Panels

Custom-sized insulated panels and reefer body kits. Materials and construction confirmed for your project.

Custom Manufacturing Process

Share body dimensions, cargo details, target temperature and any available drawings.
Confirm panel materials, door layout, required components and supply format.
Agree on drawings, quotation and supply scope before production.
Discuss inspection, packing and delivery requirements before order confirmation.

Sandwich Panel Production

Stacked insulated panels with a separate panel in the foreground.

Panel Configuration

Nominal finished panel thicknesses of 60, 80 and 100 mm correspond to XPS cores of 55, 75 and 95 mm. Finished panels also include inner and outer FRP skins and factory lamination adhesive. The complete build-up, actual finished thickness and tolerance are confirmed on the project drawings.

Workers preparing a large panel on a long production platform in a workshop.

Manufacturing Experience

Zhongshan Shengtai Refrigeration Equipment Co., Ltd. was founded in 2014. Our family’s industry experience began 10 years before the company was established. Materials and assembly details are agreed for each project.

Workers handling a large insulated panel during production.

Panel Manufacturing

Regular panels use extruded polystyrene (XPS) insulation and fiberglass-reinforced plastic (FRP) skins bonded with factory lamination white adhesive. The adhesive is included in the finished panel, not a separate local-assembly material. Polyurethane is a higher-cost option subject to order quantity; small-quantity PU orders are not offered.

Close-up of stacked panel edges showing pale core layers and outer facings.

Material Requirements

FRP skin thickness is specified per sheet and per side (1-3 mm reference range). Confirm core, skins, cut-outs, reinforcement, embedded fixings and finish on the drawings. Panel-size limits and loose-panel tolerance targets do not define assembled-body tolerances or a certified thermal rating.

FRP/XPS Panel Manufacturing References

References below apply to individual FRP/XPS panels, subject to project manufacturing confirmation.

ParameterReference value
FRP skin thickness1-3 mm per sheet / per side
Maximum mould size (length × width)9600 × 2800 mm
Maximum single finished panel (length × width)9600 × 2800 mm
Loose-panel diagonal tolerance target±2 mm
Loose-panel length and width tolerance target±1 mm

Size limits apply only to individual panels. Loose-panel tolerance targets require project manufacturing confirmation and do not define finished-thickness or assembled-body tolerances. These references are not a certified thermal rating. Honeycomb and dry cargo constructions are specified separately.

Customized Refrigerated Body

Rear view of a van with its tailgate raised and inner compartment door closed.
Rear Access
Interior view of a white cargo compartment with dark edge trim.
Compartment Interior
Rear three-quarter exterior view of a white and grey van with its tailgate closed.
Van Exterior

Panel Core Options

Illustration of a foam-core panel with white outer faces.

PU Foam Board

PU is a higher-cost alternative to our regular XPS configuration. Supply depends on order quantity; small-quantity PU orders are not offered. Panel dimensions, facings and construction are confirmed in the quotation.

White panel samples standing upright with their core structures visible.

Honeycomb Composite Panels

Honeycomb panel construction depends on core material, facings, thickness and the intended body structure. Share your application and performance requirements to confirm the proposed construction and supply scope.

View the honeycomb sandwich panel example

Illustration of a foam-core panel with white outer faces.

XPS Board

XPS is our regular insulation core for refrigerated and insulated body panels, with fiberglass (FRP) skins bonded using white adhesive. Panel thickness, skin thickness and reinforcement are confirmed for the project.

View the 80mm FRP/XPS panel example

XPS Panels for Refrigerated and Insulated Bodies

XPS-core panels can be configured for refrigerated and insulated bodies, including lightweight designs. Panel thickness, FRP skins, floor construction and reinforcement are confirmed for the body dimensions, cargo and operating conditions. Body weight depends on the complete construction; a frame adds weight. For refrigerated use, the cooling unit is matched to body size and target temperature.

White refrigerated truck with an insulated box body, viewed from the front and side.

Refrigerated Truck Body

Blue insulated truck body with double rear doors, viewed from the rear and side.

Insulated Truck Body

Need a coordinated body kit rather than panels only? Compare CKD/SKD body-kit formats and supply scope, including agreed pre-assemblies, components and selected options.

Request a Panel-Kit Quote

Send panel dimensions or body drawings (state internal or external body dimensions), application, quantity and delivery destination. Include panel build-up, openings and reinforcement requirements.

Discuss Your Panel Project